Description
Details
RF Cell Max™ successfully combines the latest revolutionary Fractional Microneedle RF technologies with Fractional Thermal RF technology in one system to achieve the most optimal treatment result for both epidermis and dermis
Besides, it also combined with cold therapy handpiece and a single insulated RF needle to achieve more treatment and better result
Features
- One System with three functions
- Fractional Microneedle RF function
- Cold therapy technology for pain relief
- Single insulated RF needle for specific target treatment
- Dynamic Linear Motor Technology
- Accurate Needle Depth Control: 0.2~3.5 mm [0.1mm Step]
- Precise RF pulse time control by 0.1 sec
- Provide Semi-Insulation Gold coated microneedles (Default) And Non-Insulated Needles (Optional)
- Fractional Multipolar Needle RF with 10 needles, 25 needles, and 64 needles.
- Fractional e-Matrix Nano RF Tips
- The noticeable result after only one treatment
Introducing Fractional Microneedle RF Machine
Technologies
8 in 1 integrated advanced technologies
Micro-Needling Therapy (wound-healing therapy)
Micro-needling delivery provides unparalleled collagen induction therapy via fractional delivery of needles into the epidermis and dermis. These micro-injuries to the skin encourage and harness the power of the body’s innate ability to re-grow and repair the skin through the physiology of collagen induction. It is a Non-surgical skin rejuvenation treatment that is widely used for skin rejuvenation, enhancement of skin elasticity, wrinkle reduction, acne scar reduction, stretch mark reduction, stimulation of hair growth, whitening, and administration of active ingredients.
Fractional RF Thermal Energy
Collagen is regenerated by delivering 55~65℃ of RF heat energy on the fibrous coat. Fiber blast and collagen fiber are stimulated through delivered RF energy which results in improvement of wrinkle, elasticity strengthens, and care for troubled skin.
Innovative Fractional Microneedle RF technology
Precisely controlled Bi-polar RF energy will be delivered into a certain depth of dermis through minimally invasive gold-coated microneedles in order to induce dermal coagulation. Microneedle penetration length can be adjusted from 0.5 to 3mm depth selectively considering the target areas depending on symptoms.
Working Principle of Fractional Microneedle RF Machine
Fractional Multipolar RF Technology
Fractional multipolar radio frequency technology places the heat energy effectively into the upper dermis where it can produce a significant increase in both collagen and elastin with minimal epidermal disruption.
The unique Sublative ergonomic applicator delivers radio frequency energy via the matrix of 64 electrodes. This fractional delivery of RF energy causes micro-epidermal ablative injuries with wider spread dermal coagulation. This initiates a strong wound-healing response in the dermal matrix while also minimizing the damage to the epidermis. Less affected tissue surrounding the matrix points may be stimulated by heat, which helps accelerate the healing process, leading to a smoother, rejuvenated appearance of the skin.
Dynamic Linear Motor Technology
Different from the existing Solenoid Type, the needle controlled by Dynamic Linear Motor Technology inserts to the skin softly and smoothly to greatly reduce the risk of bleeding and cause much less pain than another method. The Dynamic Linear Motor Technology ensures RF energy is only released after the needle is completely inserted into the treatment zone to avoid the potential risk of electric shock. Furthermore, it also enables each needle penetration with the same strength and length for maximum treatment result.
Advanced Vacuum Injection Technology
The RF Cell Max adopts accurate needling and injection technology, combined with vacuum pressure design, it can easily inject to skin with accurate depth, what's more, with genius "speed" function design, the pressure of syringe had been liberalized before micro-needle was out, it can achieve a better result.
Insulated (Semi-Insulated) Needle Emits Energy Precisely to Target Area with Less Pain and Recovery Time
Insulated needle deliver energy only at the tip of the needle, it delivers energy to the target area more precisely.
Insulation means that the epidermis is spared, no heat/energy is dispersed here, only the dermis for a more targeted effect (see below)
The insulated needle causes less pain during the treatment, makes patients feel more comfortable, and also takes less time for recovery.
Single Insulated Needle Technology for Acne Removal
Acne is a folliculitis that occurs in the sebaceous glands. If the sebaceous glands do not exist, the underlying cause of acne is not present. In order to prevent recurrent acne, it is the best way to remove sebaceous glands. It is like destroying hair roots to permanently remove hair. Similar to its principle, acne instruments use tiny insulated RF needles to prevent burns on the epidermis and only transmit high-frequency energy to the sebaceous glands. It is a safe and effective treatment.
Cryotherapy Technology
The cold therapy handpiece adopts water cooling with semiconductor cooling. It can effectively keep the temperature between -5℃~5℃ in 5 minutes. It is a perfect combination for RF treatment, because it quickly reduces the temperature of the epidermis, accelerates skin recovery, and greatly reduces downtime.
With this cold therapy handpiece, it could achieve the below benefits:
- Shrinking blood vessels, causing capillary pores to tighten, and greatly improving the pores;
- strengthen collagen fibers, make the skin firm and elastic, smooth wrinkles, crow's feet;
- Shrinking blood vessels, effectively reducing varicose veins, lifting fine ribs, and returning harmful wastes with veins are more easily purified and detoxified, and have significant effects on the fading and elimination of plaques;
- Reduce the metabolic rate, reduce the skin's redness, swelling, pain, especially for allergic skin.
Need Extra Needle Head?
Design
Genius Outward and Scientific Inner Design
Bod Case
RF Cell Max adopts high-quality Metal material for machine body cases. It makes the body shape professional, what's more, you will never worry about the case being damaged during the long overseas transportation.
Successfully combined Fractional Micro-needle RF function and eMatrix Fractional RF function in one handpiece
Handpiece and Needles
There are four kinds of needle tips to meet the treatment of different areas
The gold-coated needle is more durable and has high Biocompatibility. Patients with a metal allergy could also use it without concerning Contact Dermatitis. 10P and 25P microneedle as electrodes are able to reduce pain and allow easier dedicated depth control. It is more adaptive for small area treatment such as eye around areas and lips. 64P microneedle is recommended for large area treatment for the body. Nano head is designed for superficial layer treatment.
User-friendly software
Different from the existing Solenoid Type, the needle controlled by Dynamic Linear Motor Technology inserts to the skin softly and smoothly to greatly reduce the risk of bleeding and cause much less pain than other methods. The Dynamic Liner Motor Technology ensures RF energy is only released after the needle is completely inserted into the treatment zone to avoid the potential risk of electric shock.
Accurate Needle Depth Control: 0.2~3.5 mm [0.1mm Step]
It operates the epidermis layer and dermis layer by controlling the needle depth in a unit of 0.1mm. It is cost-effective and more convenient for different treatment conditions. Adjustable needle depth control allows for customized and reproducible treatments of delicate areas.
- Face: 0.2mm to 2.0mm
- Body: 0.2mm to 3.5mm
Precise RF pulse time control by 0.1 sec
RF Cell Max™ allows operators to precisely control each RF pulse energy by 0.1 seconds to the maximum result.
Compare
Difference between Microneedle RF and Laser
Advantage of Radio Frequency
- No matter what skin type is suitable for RF
- Easy penetration up to target area
- Less risk of side effects
Disadvantage of Laser
- Selective laser absorption
- Penetrations vary depending on the absorption rate for water, hemoglobin, melanin, etc.
Difference between RF intensity and treatment time
Short time, High power
- Thick and Wide Old Scar
- High Expectation
- Burning, Fibrosis
- Painful, Downtown
Middle Level
- Wrinkle & Tightening
- Acne Scar
- Facial & Neck Lifting
Long-time, Low power
- Pore, Active Acne
- Skin Rejuvenation
- No pain & Downtown (but lower than expectation)
RF Tips Difference
- Fractional Micro Needle RF: Minimal invasive 10, 25, 64 gold-coated electrodes
- Fractional Multipolar RF (Matrix RF): Non-invasive 64 electrodes
Penetration Depth Difference
- Fractional Micro Needle RF: Adjustable with Needle length from 0.5~3mm
- Fractional Multipolar RF (Matrix RF): Unadjustable
Target Area
- Fractional Micro Needle RF: Target area from the epidermis to deep dermis layers.
- Fractional Multipolar RF (Matrix RF): Superficial layers
Application
Facial
- Non-surgical Face Lifting
- Wrinkle Reduction
- Skin Tightening
- Skin Rejuvenation( Whitening)
- Pore Reduction
- Acne Scars
- Skin with flushing and enlarged blood vessel.
- Skin texture improvement
Body
- Scars
- Stretch Marks
- Keratosis Pilaris
- Hyperhidrosis
Recommended Parameter Setting
Microneedle RF treatment Video Guide
Result
1. Rough skin, perioral wrinkles, and nasolabial fold in a 50-year-old female at baseline and 3 months after the final session.
2. Perioral and neck wrinkle ar baseline and 4 months after one single session in a 47-year old female.
3. Wrinkles of the cheek at baseline and 4 months after the final treatment session in a 56-year-old female.
4. Crow's feet lines and eye bags in a 42-year-old female at baseline, after 2 sessions treatment.
5. Acne Scars in a 29-year old female, after 2 sessions treatment.
6. Pigmentations in a 36-year-old female, 3 sessions treatment.
*Disclaimer: The photos on this website are not intended to represent the results every patient can expect. Treatment results can vary greatly from patient to patient. iBeautyMachine.com does not guarantee specific treatment results.
Product FAQ
Why does our skin lose elasticity and start to sag?
Even with a healthy lifestyle and minimal sun exposure, our skin gradually loses its firm, youthful look. Aging, cumulative sun exposure, multiple pregnancies, and weight fluctuation are all factors that affect the strength and elasticity of the collagen fibers in our skin. This, in turn, causes wrinkles and sagging skin.
Can sagging skin be corrected non-surgically?
Skin laxity can be improved by employing novel non-invasive energy-based technologies. Microneedle RF is possible to tighten loose skin and promote the production of new, healthier collagen
What is the RF Cell Max technology?
The RF Cell Max technology is an advanced fractional microneedle RF technology that enables fractional skin resurfacing and treatment of wrinkles and scars. RF Cell Max energy is delivered to the skin in a fractional manner via an array of micro-electrode pins. RF Cell Max creates small zones of treated tissue in the epidermal areas which are in direct contact with the microelectrodes and deliver deep heat into the dermis. The fractional manner leaves intact zones in between the targeted areas which serve as a pool of cells reservoir that promotes a faster more effective healing process. In the epidermis, the affected spots result in small scabs that shed off the skin after a few days, leading to an improved skin tone and texture. In the dermis, treatment induces remodeling of dermal collagen (neocollagenesis) and of other dermal components. RF Cell Max treatment enables safe, tolerable, and effective skin rejuvenation.
What should I expect during treatment?
40° C (hot shower temperature). Your skin temperature will be constantly monitored. Depending on the size of the treatment area, treatment may take between 30-45 minutes. The treatment is relaxing, pain-free, and carries no side effects.
How long does RF Cell Max treatment take?
The topical anesthetic cream requires 20 to 30 minutes to take effect prior to treatment, and then the treatment takes 20 to 30 minutes, including aftercare. So, each session requires approximately 1 hour.
How many treatments are required to see the results?
According to your treatment program, your physician will offer a series of treatments, up to six, in intervals of one to two weeks. You should start to see improvement in your skin following the second treatment and additional improvement will gradually appear as the treatment course progresses. As new healthier collagen is formed, tighter, more natural-looking, and firmer skin will be produced. The gradual improvement in your skin will continue even after the completion of the treatment series.
Is the RF Cell Max treatment painful?
With the correct application of topical anesthesia, it is virtually painless. It is also possible to treat to a 1mm depth without topical anesthesia.
How long is recovery after RF Cell Max treatment?
You may experience transient erythema on the treated areas for 3-4 hours initially. Occasionally, a fine scab will be formed on the skin – do not be concerned, this is an expected part of the healing process.
What is the recommended RF Cell Max treatment regimen?
The typical interval between sessions is once every 3 weeks. Most patients see excellent results following 4-5 treatments. This may vary according to your skin condition and your physician will be better able to assess and advise you of this.
Are there any precautions after RF Cell Max treatment?
Avoid cleansing until after the erythema has resolved itself. Cleanse your skin with cool water and dab or pat lightly with a towel. Avoid hot water. Sunscreen should be applied every day to protect your skin and you should limit sun exposure during the treatment course.
What side effects can I expect?
After the treatment, the skin may look sunburned, with large areas of redness. This redness usually fades within a few days and can be covered with makeup.
Specification
Specification
Fractional Micro-needle RF | RF Type: Fractional RF RF Frequency: 2-4MHz RF Intensity: Eye Treatment: Level 1- 8; Face Treatment: Level 1- 10; Body Treatment: Level 1-12 RF Pins: 10 Pins; 25 Pins; 64Pins and Nano Needle Spot Size: 1.2*1.2cm; 2*2cm; 4.1*4.1cm Needle Depth: 0.20-3.5mm Adjustable Needle Out Interval: 250ms-600ms Adjustable RF Delay: 1ms-10ms Adjustable |
---|---|
Fractional Multi-polar RF (Dot Matrix RF) | When choosing nanoneedle, it will work as an eMatrix non-invasive fractional RF |
Cold&Hot Therapy | Cold Therapy Handpiece |
PDT | Blue: 470nm±5nm |
Cooling System | Air Cooling |
Screen | 10.4 inch Colorful Touch Screen |
Voltage | AC 100~240V 50/60Hz |
Output Power | 250W |
Materials | ABS plastic |
Package Size(cm) | 118*122*60cm |
Gross Weight | 58Kg |
ODM&OEM | Yes |
Shipping&Payment
Shipping
Delivery country: currently we only deliver to the USA, Canada, Australia, the UK, New Zealand. EU, Japan, South Korea, Singapore, China, Malaysia and Vietnam.
Importation duty: iBeautyMachine.com covers importation duty.
Excludes: special items such as gas or liquid.
Remote regions may cause extra for delivery to the door.
Please refresh the checkout page if you change the cart in case the free shipping option doesn't show up.
NOTE:
Warehouse working time: 9:00 am~ 6:pm (Monday to Friday; GMT+8).
Payment
Please note: We DO NOT accept Credit Card payments for product value of a single unit over 1,500 USD.
If you are not happy with the order and the product, you can ask for a refund after receiving the package. Our customer support will assist you with it.
We do not add taxes, VAT, or any other hidden charges. You pay us what you see on your invoice, for example, Goods Subtotal + Shipping Costs (does not include duties). Please find out as much as you can about import taxes in your own country before purchasing an item. In special cases, you may need to pay import duties on certain goods. You can contact us for further assistance on any of this.
Reviews
Tags
Product Questions
Total 1 question(s)
Are this and/or your machines FDA approved?
Are they CE certified?
Question submitted by: Lasse on: 2022-11-24 23:53:27
We have CE certificates only.
Answer submitted by: sales on: 2022-11-25 18:35:26